PerkinElmer

万博AR彩票官方网站(GC)

OF

⮱Clarus系列仪器兼具灵活性,。易用性和灵敏度,。我们の万博AR彩票官方网站仪可日复一日提供准确高效の分析结果,。与几乎与所有样品处理系统兼容,。包括我们世界级のTurboMatrix顶空进样器和热脱附仪,。我们服务の行业包括政府机构、食品制造商、消费品企业、炼油厂、环境实验室等,。⮰

  • 测试食品质量、污染物和香精香料
  • 监测水、土壤、空气中VOCs及SVOCs含量
  • 确保消费品质量,。包括塑料
  • 分析润滑油の质量和一致性
  • 符合全球法规要求
  • 通过自动进样器提升样品处理效率

⮱我们の丰富のGC应用集可以满足您特定の实验室需求

产品与服务 (1559)
Filters:

Filters :

产品类型
  • Consumables (1287)
  • Accessories (260)
  • Software and Informatics (1)
  • Service Parts (5)
  • Instruments (6)
应用
  • Mass Spectrometry (40)
帽和载波风格
  • Screw Top (31)
  • Crimp Top (25)
  • Snap Top (11)
颜色
  • Clear (44)
  • Silver (13)
  • Black (9)
  • Blue (17)
  • Yellow (2)
  • Gray (5)
  • Green (2)
  • White (1)
  • Amber (8)
  • Orange (1)
  • Purple (4)
  • Red (4)
浓度
  • 1000 µg/mL (3)
  • 2000 µg/mL (18)
膜厚
  • 0.25 µm (89)
  • 1.0 µm (70)
  • 0.5 µm (48)
  • 3.0 µm (20)
  • 0.1 µm (22)
  • 1.5 µm (18)
  • 0.15 µm (14)
  • 2.55 µm (8)
  • 10.0 µm (4)
  • 5.0 µm (8)
  • 1.4 µm (8)
  • 1.27 µm (2)
  • 0.4 µm (5)
  • 0.85 µm (3)
  • 0.33 µm (12)
  • 1.8 µm (8)
  • 0.83 µm (1)
  • 20.0 µm (1)
  • 0.6 µm (1)
  • 0.52 µm (2)
  • 0.18 µm (2)
  • 2.0 µm (3)
  • 0.3 µm (1)
  • 1.12 µm (1)
  • 0.42 µm (3)
  • 0.2 µm (3)
  • 50.0 µm (1)
  • 0.34 µm (1)
内径
  • 0.3 mm (80)
  • 0.25 mm (81)
  • 0.2 mm (74)
  • 11 mm (45)
  • 0.32 mm (46)
  • 0.53 mm (40)
  • 0.5 mm (56)
  • 1/16 in (31)
  • 0.15 mm (13)
  • 1/8 in (22)
  • 10 mm (10)
  • 2 mm (13)
  • 9 mm (25)
  • 4 mm (21)
  • 20 mm (15)
  • 0.4 mm (12)
  • 13 mm (3)
  • 1/4 in (11)
  • 8 mm (12)
  • 2.0 mm (12)
  • 0.11 mm (7)
  • 1/4 to 1/8 in (4)
  • 0.8 mm (4)
  • 4.0 mm (5)
  • 6 mm (2)
  • 1/4 to 1/4 in (1)
  • 1/16 to 1/32 in (1)
  • 1.25 mm (1)
  • 0.45 mm (6)
  • 1/4 to 1/16 in (1)
  • 0.6 mm (1)
  • 2.4 mm (1)
  • 0.37 mm (1)
  • 1 mm (4)
  • 0.4 mm (2-hole) (1)
  • 1/8 to 1/4 in (1)
  • 3 mm (1)
  • 0.5 mm (2-hole) (1)
  • 0.18 mm (3)
  • 0.02 in (1)
  • 0.24 mm (1)
  • 1/8 to 1/16 in (4)
  • 0.1 mm (6)
长度
  • 21-30 (178)
  • 51-100 (138)
  • 11-20 (95)
  • 41-50 (36)
  • 0-10 (27)
  • 31-40 (5)
  • 101-200 (5)
  • 301-400 (1)
材料
  • Stainless Steel (66)
  • PTFE (50)
  • Clear Glass (29)
  • Brass (28)
  • Glass (14)
  • Metal (12)
  • Graphite (9)
  • Amber Glass (8)
  • Graphite/Vespel (7)
  • Silica (3)
  • PTFE/Buytl (2)
  • Clear Plastic (2)
  • PTFE/Red Rubber (2)
  • Phenolic (1)
  • Black Viton (1)
  • Ceramic (1)
  • Butyl (1)
  • Silicone (1)
  • Butyl (gray) Stopper (1)
  • Vespel (1)
  • Polyimide (1)
  • Polypropylene (1)
  • Aluminum/PTFE (1)
  • PTFE/Silicone (1)
温度-最高
  • 30-40 (9)
  • Over 100 (4)
温度-最低
  • 10-20 (12)
  • 0-10 (3)
  • 90-100 (1)
型号兼容
  • Solid Phase Extraction (SPE) (241)
  • Clarus 480 (2)
  • Clarus 690 (2)
  • Clarus 590 (2)
  • Clarus 680 (2)
  • Clarus 580 (2)
  • Clarus 480, 580, 680 both CAP and PSS injector for Clarus 590 and 690 only for PSS injector (2)
  • Quechers Dispersive SPE (19)
外径
  • 0.47 mm (12)
  • 6.2 mm (25)
  • 4 mm (13)
  • 0.5 mm (16)
  • 5 mm (1)
  • 11 mm (4)
  • 0.8 mm (1)
  • 6.3 mm (1)
  • 2 mm (1)
  • 6 mm (1)
  • 8 mm (1)
  • 0.63 mm (15)
  • 0.72 mm (4)
阶段
  • 100% Dimethyl Polysiloxane (46)
  • Dimethyl Polysiloxane (15)
  • Polyethylene Glycol (38)
  • Trifluoropropylmethyl polysiloxane (34)
  • Diphenyl Dimethyl Polysiloxane (40)
  • 5% Diphenyl/95% Dimethyl Polysiloxane (10)
  • 5% diphenyl / 95% dimethyl polysiloxane (13)
  • Cycanopropylmethyl-phenylmethylpolysiloxane (7)
  • Phenyl Methyl Polysiloxane (24)
  • Dimethyl Polysiloxane (1)
  • 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane (17)
  • 5% diphenyl / 95% dimethyl polysiloxane (3)
  • 5% Diphenyl and 95% Dimethyl Polysiloxane (3)
  • Betadextrin (1)
  • Alumina (3)
  • phenyl group in the polymer backbone (2)
  • Cyanoprpylphenyl dimethyl polysiloxane (19)
  • 6% cyanopropylphenyl / 94% dimethylpolysiloxane (2)
  • 100% dimethyl polysiloxane (3)
  • No Phase Coating (2)
  • Cyclosil (1)
  • (6%-cyanopropylphenyl)-methylpolysiloxane (7)
产品品牌名称
  • Gas Purifier (50)
  • Elite-1 (52)
  • Elite-200 (34)
  • Elite (21)
  • Elite-5 (28)
  • Elite-WAX (19)
  • Elite-5 Anime (10)
  • Torion® (33)
  • Elite-CL Pesticides (11)
  • Elite-225 (7)
  • TurboMatrix (9)
  • Elite-17 (15)
  • Elite-WAX ETR (16)
  • Elite-5ms (17)
  • Velocity-1 (6)
  • Clarus (4)
  • Elite-17ms (5)
  • Elite-1701 (19)
  • Elite-FFAP (7)
  • Custodion® (5)
  • Elite-35 (5)
  • Elite-Alumina (3)
  • Velocity-5 (3)
  • Elite-VMS (10)
  • Elite-1ht (3)
  • Elite-SimDist (1)
  • Elite-5ht (High Temperature) (3)
  • Elite-17ht (High Temperature) (3)
  • GemTip (3)
  • Elite-502.2 (4)
  • Elite-Volatiles (6)
  • Elite-RX (4)
  • Arnel (5)
  • Elite-624 (7)
  • Elite-PONA (1)
  • Clairion® (2)
  • Elite-Siltek (2)
  • Elite-XLB (5)
  • Elite-Betacyclodextrin (1)
  • Elite-MTBE (1)
  • Green Injection Port Septa (1)
  • Elite-TPH (2)
  • Elite-23 (1)
  • Elite-BAC (6)
  • BTO Orange Injection Port Septa (1)
  • Elite-Q PLOT (2)
  • Elite-608 (3)
  • Elite-1301 (7)
  • Merlin MicroSeal (2)
  • Elite-BAC Advantage (1)
  • Elite-Molesieve PLOT Phase (1)
  • Elite-35ms (3)
  • Elite-Cyclosil (1)
  • Velocity-Wax (3)
  • Elite-5 Amine (1)
产品组
  • Columns (168)
  • Cap/Septa (43)
  • Replacement Part (40)
  • Syringe Filters (32)
  • Gas Purifier (25)
  • Ferrule (40)
  • Organic (43)
  • Add-on Kit (31)
  • Kit (24)
  • Union (32)
  • Autosampler Syringe (12)
  • Ultra Clean Filter (23)
  • Well plates (32)
  • Gas Tight Syringe (15)
  • Regulator (4)
  • Zero Air Generator (13)
  • Application Packs (14)
  • Vial (21)
  • Vial Insert (15)
  • GC Syringe (12)
  • Decapper (6)
  • Nut (9)
  • Replacement Parts (13)
  • Vacuum Manifold Kits & Accessories (14)
  • Adapters and Replacement Parts (2)
  • Hydrogen Generator (4)
  • Replacement Needle (11)
  • Add-On Kits (20)
  • Accessory (14)
  • Starter Kits (3)
  • Pump (1)
  • Leak Detector (3)
  • Disposable Syringes (4)
  • Starter Kit (5)
  • Bubble Flow Meter (2)
  • Ultramicro Syringe (5)
  • Vial Sleeve (1)
  • Tee (4)
  • S-Swafer (2)
  • Standard Tungsten Filament (1)
  • Scribes (1)
  • Advanced Filter System (2)
  • Clean-up Kits (16)
  • Benchtop Crimper (3)
  • Cartridges (6)
  • Injection Port Septa (4)
  • Crimpers (5)
  • Zero Air Generator - Ultra (1)
  • Hydrogen Generator - Ultra (4)
  • Tubing (1)
  • Sample Support (1)
  • Vial Rack (1)
  • Ultra Clean (1)
  • Filament (1)
  • Trays and Racks (2)
  • Fittings (1)
  • Tool Kit (1)
  • Silanized Glass Wool (1)
  • Plug (5)
  • D-Swafer (2)
  • Bakeout Disk (1)
  • Cross (1)
  • Flow Meter (2)
  • MiniTemp Handheld Laser (1)
  • Outer Liner (1)
  • GC Compressor (6)
  • Trap (1)
  • Column Selection Kits (7)
  • GC (1)
  • Extraction Kits (3)
  • Swafer Kit (2)
  • Filter Replacement Part (3)
  • Hydrogen Generator - Replacement Parts (5)
放射性同位素
  • Ni-63 (4)
标准型
  • Ketones for Method 8260B (1)
  • Method 8270C Standards (2)
  • Method 8270C Surrogates (2)
  • Method 505 (1)
  • Method 525.2 (2)
  • Method 8260B Standards (2)
  • Pesticides (3)
  • Mix B Purgeable Gases for Methods 8260B/524.2 (1)
  • ASTM D-6584 (1)
  • Volatile Organics Combination Blend (1)
  • Method 524.2 (3)
  • Method 625 (5)
  • Method 608 (1)
  • Method 624 Standards (5)
  • Method 8270C Mixes (3)
  • Test Mix (3)
  • Method 8082 PCB's Standards Kit (1)
类型
  • Screw Top (47)
  • Crimp Top (31)
  • Snap Top (17)
技术
  • Capillary (145)
  • Capillary - General Purpose (89)
  • Cartridge (48)
  • Conventional (33)
  • Capillary - Specialty Application (26)
  • Custom Packed Columns (18)
  • Gas Chromatography (4)
  • Gas Chromatography/Mass Spectrometry (2)
  • Conventional-Guard (2)
技术类型
  • Autosampler (94)
  • Capillary Split/Splitless (18)
  • Chromatography (15)
  • Packed Colored (6)
  • Packing material (1)
  • Headspace (12)
  • Packed Clear (12)
  • PSS injector, CAP injector (2)
  • O-ring (1)
  • PSS Injector, CAP injector (1)
  • Programmed Temperature Split/Splitless (PSS) (9)
  • Tubing Kits and Spares (GC) (1)
  • GC, GC/MS, Gas Chromatography, SPME (2)
类型
  • Oxygen,Moisture,Hydrocarbon (16)
  • Fixed (19)
  • Removable (29)
  • Oxygen (3)
  • Moisture,Hydrocarbon (4)
  • Oxygen,Moisture (3)
  • Moisture,Oil,Dust (1)
  • Hydrocarbon (3)
  • Air Monitoring (1)
  • Moisture (5)
体积
  • 0-50 (1)
体积容量
  • 2 mL (114)
  • 6 mL (61)
  • 3 mL (67)
  • 0.22 µm (16)
  • 15 mL (29)
  • 1.2 mL (21)
  • 0.45 µm (16)
  • 1 mL (42)
  • 0.5 µL (7)
  • 250 µL (10)
  • 30 L/min (3)
  • 10 µL (7)
  • 5 µL (6)
  • 500 µL (5)
  • 10 mL (3)
  • 25-500 µL (2)
  • 1.5 L/min (2)
  • 2.5 mL (1)
  • 25 µL (3)
  • 3 L/min (1)
  • 300 µL (4)
  • 250 mL/min (2)
  • 4 mL (1)
  • 100 µL (7)
  • 160 mL/min (2)
  • 1 µL (2)
  • 22 mL (1)
  • 200 µL (3)
  • 1000 mL/min (1)
  • 15 L/min (3)
  • 5 mL (5)
  • 25 mL (6)
  • 500 mL/min (2)
  • 20 mL (1)
  • 2 uL (1)
  • 6 L/min (1)
  • 150 µL (1)
  • 50 µL (4)
  • 3.5 L/min (2)
  • 5 L/min (2)
  • 400 µL (1)
  • 50 mL (3)

1-12 の 1559 产品与服务

  • Jump to:
Business Insights (18)
Filters:

Filters :

資源庫
  • Application Note (11)
  • Brochure (2)
  • Flyer (1)
  • Product Note (1)
  • Case Study (1)
  • FAQ (1)
  • Technical Note (1)

1-12 の 18 Business Insights

  • 产品手册

    Clarus 590 and 690 Brochure

    In today’s budget-constrained, yet highly competitive laboratory environments, the samples you’re being asked to analyze - whether food, pharmaceutical, petrochemical, or environmental - are increasingly difficult. But for some labs, having a dedicated GC for every application isn’t an option. For them, a GC that can do it all isn’t just a nice-to have, it’s a necessity.

  • 产品手册

    TurboMatrix Thermal Desorbers for Gas Chromatography

    For laboratories analyzing everything from air quality to flavors and fragrances, thermal desorption offers a faster, easier, more cost-efficient way to prepare samples for GC or GC/MS analysis. Ideal for the trace-level measurement of volatile organic compounds (VOCs)—as well as most semi-volatile chemicals—thermal desorption lets you avoid time-consuming, manual, solvent-based sample preparation in favor of a simple, streamlined, automated approach. It also delivers the added benefits of superior throughput and enhanced sensitivity.

  • 产品说明

    Ozone Precursor System

    The analysis of C2 to C12 volatile organic ozone-precursor compounds can present a serious technical challenge to the analytical chemist. Low concentrations in the atmosphere coupled with the need to monitor frequently to assess diurnal variations means that a preconcentration step of the sample before analysis by thermal desorption is required. While the samples can be collected in the field and returned to the laboratory, remote, field-based analysis is desired which allows reduced data turnaround time, minimizes sample collection hardware and permits the presence or absence of VOCs to be correlated with meteorological data. In the field, low-molecular-weight C2 VOCs can be trapped on solid adsorbents if those adsorbents are cryogenically cooled.

  • 应用文献

    Analysis of Volatile Organic Compounds (VOCs) in Air Using US EPA Method TO-17

    Optimized methods are needed for the analysis of toxic compounds in air to understand the impact to human health. People breathe approximately 20,000 liters of air a day so this concern is significant. EPA Method TO-17 is used to determine toxic compounds in air after they have been collected onto sorbent tubes. This application note demonstrates that the PerkinElmer TurboMatrix™ Thermal Desorber and the PerkinElmer Clarus® SQ 8 GC/MS will meet and exceed the criteria set forth in EPA method TO-17. Detailed instrument method parameters are presented, with precision, recovery, linearity and detection limit results.

  • 应用文献

    Ambient Air Monitoring - U.S. EPA PAMS

    Air pollution is a global concern. Ground-level ozone has become an increasingly important issue in developed nations, as the health effects of smog are more clearly understood. The monitoring of VOC ozone precursor compounds will continue to play a role in defining and reducing air pollution in developed and developing nations in the next decade. The data presented here shows the excellent results of improved separation via Elite-624Sil MS column with real world samples, simplified column connections to the Dean Switching device and trap with modernized triple bed trap with guard zone technologies.

  • 应用文献

    Residual Solvents in Pharmaceuticals by USP Chapter 467 Methodology

    The synthesis of active pharmaceutical ingredients (API) may require multiple reaction steps that produce undesirable reaction byproducts or utilize various solvents that have to be removed from the finished product. These solvents and byproducts may be measured with headspace gas chromatography for those volatile residual organic solvents according to the USP chapter 467 method. Method USP 467 classifies residual solvents into three classes according to toxicity; class 1 solvents are to be avoided unless there is strong justification, class 2 solvents are those that should be limited due to toxicity concerns.

  • 应用文献

    Identification of VOCs in In-Vehicle Interior

    Customer complaints of odors within a new car are rising with the increasing number of new car buyers. Although odors can be subjective, it is now well known that the new car smell is the result of chemicals emitted from the in-vehicle interior components such as the dashboard, interior panels, seat coverings, flooring materials, and so on. This application note describes a method for the automotive industry that provides a qualitative analysis and the olfactory character of each component using the TD-GC/MS-Olfactory Port.

  • 应用文献

    Analysis of Volatile Organic Compounds in Air by Online TD-GC

    Volatile Organic Compounds (VOCs) have been identified as a major source of air pollution, and as such, have been regulated as a cause of both primary and secondary pollution, such as photochemistry smog. The U.S. Environmental Protection Agency (U.S. EPA) regulates 189 hazardous air pollutants under the Clean Air Act (CAA) of 1990, 51% of which are VOCs. The CAA offers further regulation and guidance for the monitoring of VOCs and ozone pollution in ambient air with a list of 57 ozone-precursor target analytes monitored under U.S. EPA’s Technical Assistance Document for Sampling and Analysis of Ozone Precursors, EPA/600-R-98/161 (1998)1, as well as the requirement of states to establish Photochemical Assessment Monitoring Stations (PAMS). This paper details an application for VOC monitoring with an extended target compound list utilizing a PerkinElmer TurboMatrix 300 TD and PerkinElmer Clarus® 580 GC. The application note demonstrates results with good repeatability, linearity and detection limits.

  • 应用文献

    The determination of low level benzene, toluene, ethyl benzene and xylenes (BTEX) in Drinking Water by Headspace Trap GC/MS

    BTEX are regulated toxic compounds while benzene is also an EPA target carcinogen. The investigation of these compounds, especially in drinking water at low levels, is critical to protect public health. This application note focuses on exceeding the current EPA detection limit requirement for BTEX while meeting and/or exceeding all other criteria in EPA method 524.2 for these analytes.

  • 应用文献

    Fast Simulated Distillation Analysis by Modified ASTM D2887, D7169, D6352, and D7500

    To meet the demands of complex petrochemical testing, our new Clarus® 590 and 690 gas chromatography (GC) instruments are preconfigured to provide a turnkey solution for a wide range of applications, including Simulated Distillation. We deliver a complete, ready-to-go system for faster, more efficient analysis in compliance with ASTM methods. Discover how the Clarus GC instruments enable the superior sensitivity and throughput you need for your most critical applications – plus the versatility to handle more.

  • 应用文献

    Determination of t-Butyl Methyl Ether (MTBE) in Water and Soil

    As an alternative to tetraethyl lead, t-Butyl methyl ether (MTBE) has been widely used as an octane enhancer for gasoline. Studies have found increasingly high levels of MTBE in groundwater, often a result of accidental spills or leaking underground storage tanks. In this paper, a method for the determination of MTBE in water and soil was established using the PerkinElmer Clarus® 690 GC/FID with the TurboMatrix™ HS-40 Trap.

  • 应用文献

    Cannabis Analysis: Potency Testing Identification and Quantification of THC and CBD by GC/FID and GC/MS

    This application note will concentrate on the potency identification and quantification of THC and CBD in cannabis by Gas Chromatography. Other application notes will cover potency by HPLC, pesticide analysis and residual solvent analyses. Analysis of cannabis has taken on new importance in light of legalized marijuana in several states of the USA. Cannabis contains several different components classed as cannabinoids. Primary cannabinoids of interest are tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN). Positive identification and quantification of the THC/CBD ratio is a primary objective in the analysis of cannabis. Cannabis is analyzed for several different purposes.

  • Jump to: