PerkinElmer

万博AR彩票官方网站 (ICP-OES)

OF

⮱可靠性和高性能是我们ICP多元素检测解决方案の标志,。我们在ICP-OES和ICP-AES技术方面拥有悠久和卓越の领导地位,。我们の分析平台是为满足世界客户の实际应用需求而设计の,。确保实现准确の多元素分析,。⮰

⮱我们还提供广泛の消耗品和附件 - 包括量身定制の自动进样系统,。专业の培训和售后支持使您可轻松应对各种挑战,。⮰

产品与服务 (1358)
Filters:

Filters :

产品类型
  • Consumables (1134)
  • Accessories (203)
  • Service Parts (17)
  • Software and Informatics (1)
  • Instruments (3)
浓度
  • 1000 µg/mL (173)
  • 1000 µg/g (36)
  • 10000 µg/mL (17)
  • 10 µg/mL (16)
  • 500 µg/g (11)
  • 100 µg/g (11)
  • 10 µg/g (10)
  • 50 µg/g (9)
  • 30 µg/g (9)
  • 900 µg/g (8)
  • 300 µg/g (8)
  • 10 µg/L (5)
  • 100 µg/mL (3)
  • 30 mg (3)
  • 40 mg (2)
  • 2 mg (2)
  • 10 mg (2)
  • 1 µg/L (2)
  • 0.1 mg (2)
  • 0.5 mg (2)
  • 3 mg (2)
  • 1 mg (2)
  • 20 µg/mL (2)
  • 1,000 µg/g (2)
  • 5000 µg/g (2)
  • 70 mg (2)
  • 6 mg (2)
  • 1.5 mg (2)
  • 15 mg (2)
  • 50 µg/g (1)
  • 200 µg/L (1)
  • 5,000 µg/g (1)
  • 1,000 µg/mL (1)
  • 15 µg/g (1)
  • 20 µg/g (1)
  • 25 µg/g (1)
  • 2 µg/mL (1)
  • 10 2 µg/L (1)
  • 1,500 µg/g (1)
  • 5000 µg/mL (1)
  • 2 µg/L (1)
  • 1000 µg/g (1)
  • 5 µg/g (1)
深度
  • 84.0 cm (1)
  • 83.0 cm (1)
  • 63.5 cm (1)
级别
  • Pure (149)
  • Pure Plus (40)
内径
  • 0.5 mm (11)
  • 1 mm (8)
  • 0.8 mm (7)
  • 1.30 mm (3)
  • 0.25 mm (5)
  • 2.06 mm (1)
  • 0.19 mm (3)
  • 1.6 mm (4)
  • 1.52 mm (1)
  • 0.6 mm (2)
  • 2.0 mm (3)
  • 3.0 mm (1)
  • 1.65 mm (1)
  • 0.44 mm (1)
  • 2.79 mm (1)
  • 1.14 mm (4)
  • 5 mm (1)
  • 0.51 mm (2)
  • 3.18 mm (1)
  • 0.38 mm (2)
  • 1.42 mm (1)
  • 0.80 mm (2)
  • 1.00 mm (1)
  • 1.85 mm (2)
  • 1.02 mm (2)
  • 1.2 mm (2)
  • 0.76 mm (5)
  • 0.64 mm (1)
长度
  • 51-100 (3)
材料
  • PVC (69)
  • PFA (34)
  • Solva (31)
  • Quartz (29)
  • PTFE (27)
  • Glass (20)
  • Alumina (16)
  • Polypropylene (15)
  • CTFE (10)
  • Santoprene (9)
  • PEEK (9)
  • Sapphire (9)
  • Silicone (6)
  • Viton® (6)
  • Viton (6)
  • PEEK/PTFE (5)
  • Solvent Flex (5)
  • Stainless Steel (4)
  • Corrosion Resistant (3)
  • Teflon (3)
  • Peek/PTFE (3)
  • Pharmed (2)
  • Fluoropolymer (2)
  • Ceramic (1)
  • Fused Silica (1)
  • Alumina Ceramic (1)
  • Ryton (1)
  • TFE (1)
  • PPS (1)
  • Solvent Resistant (1)
  • Polyethylene (1)
  • ETFE (1)
型号兼容
  • Avio (183)
  • Sample Preparation Blocks (62)
  • Optima 5x00 DV (51)
  • Optima 2x00 DV (47)
  • Optima 4x00 DV (49)
  • FAST (19)
  • Inductively Coupled Plasma (12)
  • Optima 7x00 DV (47)
  • NexION 2000 (7)
  • Avio 500 (50)
  • Optima 7100 (2)
  • Avio 200 (47)
  • Optima 7200 (2)
  • Optima 4300 V (19)
  • ELAN 6x00 (7)
  • NexION 300 (6)
  • Optima 7000 DV (1)
  • Optima 7300 DV (2)
  • Optima 8x00 (55)
  • Optima 8300 (2)
  • ELAN 5000 (6)
  • ELAN DRCs (6)
  • Optima 7300 V (19)
  • NexION 350 (6)
  • NexION 1000 (6)
  • ELAN 9000 (6)
  • Optima 8000 (2)
  • Optima 3x00 RL (8)
  • Optima 5300 V (19)
  • Model 3300 (1)
  • Optima 3000 SCR (4)
  • Optima 3000 XL (1)
  • Optima 3000 DV (4)
  • Optima 3x00 DV (17)
  • SC-2 Autosamplers (1)
  • AAnalyst 100 (1)
  • SC-4 Autosamplers (1)
  • Optima 3x00 XL (8)
  • Optima 2x00 (2)
  • Optima 2100 (1)
  • Solid Phase Extraction (SPE) (1)
  • Optima 5x00 (5)
  • Optima (7)
  • AAnalyst 700 (2)
  • Model 5100 PC (1)
  • Plasma 40 (1)
  • AAnalyst 300 (1)
  • AAnalyst 400 (1)
  • AAnalyst 800 (1)
  • NexION (5)
  • Optima 3000 SCX (6)
  • AAnalyst 200 (1)
  • Optima 7x00 (5)
  • ASXPRESS PLUS (2)
  • ELAN 9000 Controller Side (1)
  • Titan (1)
  • Model 3100 (1)
  • Model 3110 (1)
  • Optima 4x00 (5)
  • Optima 7000 (1)
Number of Elements
  • Multiple (165)
  • Single (254)
产品品牌名称
  • ESI (19)
  • PerkinElmer (7)
  • MEINHARD (10)
  • SeaSpray (2)
  • Avio (2)
  • OilExpress (1)
  • Slurry (1)
  • Peltier (11)
  • VeeSpray (1)
  • Mira Mist (9)
  • Conikal (2)
  • Cetac (2)
  • MicroMist (11)
  • IsoMist (2)
  • Cinnabar (1)
  • DuraMist (2)
  • Teledyne CETAC (2)
  • Capricorn (1)
  • MicroFlow (9)
  • GemTip (12)
  • OpalMist (3)
  • GemCone (4)
  • Ari Mist (1)
  • D-Torch (5)
  • OilPrep (3)
  • Tracey (1)
  • Titan (1)
产品组
  • Inorganic (319)
  • Metallo-Organic (172)
  • ESI MP2 Two-Stop (77)
  • Nebulizers (55)
  • Replacement Parts (25)
  • Capillary Assemblies and Tubing (32)
  • Injectors (46)
  • Probes (24)
  • Two-Stop (41)
  • Trays and Racks (40)
  • Rotors and Stators (26)
  • Filter Replacement Part (8)
  • Probes and Holders (12)
  • DigestionTubes (16)
  • Temperature Controlled Spray Chambers (13)
  • Vessels and Spares (23)
  • Screw Caps (7)
  • Adapters and Replacement Parts (12)
  • SPB Fume Hoods (4)
  • ICP-OES Compressor (9)
  • Capillary Tubing (11)
  • O-Rings (15)
  • Three-Stop (9)
  • Connectors (4)
  • Valves (7)
  • Torches (5)
  • Carier Lines (2)
  • Racks (12)
  • Regulator (5)
  • Accessories (8)
  • Nebulizer Tips (3)
  • Gas/Liquid Separator and Replacement Parts (5)
  • Replacement Part (2)
  • Watch Glasses (4)
  • Rinsing Kit Replacement Parts (5)
  • Start Up Kits (8)
  • Turntables (7)
  • Hose Assembly (3)
  • Cleaning Tools (3)
  • Mixing/Separation Assembly (1)
  • Microtiter Plates (4)
  • Tubing (3)
  • Lip Forming Seals (5)
  • Adapters (14)
  • Valve Replacement Parts (4)
  • Mixing Block (1)
  • Torch Replacement Parts (1)
  • Acetylene Filter (1)
  • Gas Containment Manifold (3)
  • Filter Element (8)
  • Scoop (1)
  • Tubes and Vials (5)
  • Flashback Arrestor (1)
  • Screw Driver (1)
  • Spray Chambers (8)
  • Mass Flow Controllers (2)
  • Noise Enclosure (1)
  • Consumable Run Kits (2)
  • oneFAST Systems (1)
  • Luers (5)
  • Probe Replacement Parts (6)
  • Caps and Plugs (1)
  • Vacuum Pump (1)
  • Compressor Replacement Parts (5)
  • SPB Replacement Parts (1)
  • Columns (1)
  • Cooling System (5)
  • Union (1)
  • Fittings (1)
  • Gas Purifier (1)
  • Flow Injection Furnace Supplies (3)
  • Weighing Cups (2)
  • Desolvation Accessory (6)
  • End Caps (1)
  • Tubing and Replacement Parts (1)
  • DigiFILTERs (3)
  • Injector Replacement Parts (4)
  • Sample Introduction Kits (6)
  • Pipette Tips (1)
  • Spares Kits (1)
  • O-Ring Kit (2)
  • Bottles and Containers (4)
  • Air Filter Assembly (1)
  • Vacuum Pumps (3)
  • FIAS/FIMS Cell Replacement Parts (6)
  • Air Dryer (1)
  • Power Conditioner (2)
  • Stirrers and Replacement Parts (1)
  • Blower and Vent (2)
  • Outer Tubes (1)
  • Hook (1)
标准型
  • Single-Element (227)
  • Instrument Calibration (48)
  • Sulfur (17)
  • V-21 + K Wear Metal (18)
  • V-23 Wear Metal (21)
  • Multi-Element (11)
  • Mixed Calibration (6)
  • Contract Lab Program Modification Set (9)
  • Viscosity Reference (9)
  • Matrix Oils and Solvents (6)
  • Acid Number (12)
  • Internal (3)
  • AA Standards (8)
  • Base Number (13)
  • Glycerol (1)
  • Interference Solutions (6)
  • Environmental (5)
  • Metal Additive (1)
  • Water Pollutant (7)
  • Internal (5)
  • V-21 Wear Metal (21)
  • Spike (2)
  • Nitric Acid Blanks (2)
  • Initial Calibration Verification (1)
  • Contract Required Detection Limits (1)
  • Analytes (1)
  • Low UV Standard (1)
  • Initial Calibration Veri�tion (1)
  • Metal Additive (3)
  • USP/ICH Standards (1)
  • Fuel Dilution (2)
  • Quality Control (3)
  • Interference Check (3)
  • Calibration (2)
  • Universal Data Acquisition (1)
  • Environmental (2)
  • Aqueous (1)
  • Water Blank (2)
  • Biodiesel (4)
  • Initial Calibration Verification (1)
  • Installation (1)
类型
  • Standard (94)
  • Flared (35)
技术
  • IR (1)
  • ICP Optical Emission Spectroscopy (1)
技术类型
  • Peristaltic Pump Tubing (130)
  • ICP-OES (82)
  • ICP-MS (9)
  • Pump Tubing (8)
  • Flow Injection Tubing (10)
  • Atomic Spectroscopy (2)
  • AA (1)
  • ICP Optical Emission Spectroscopy (1)
类型
  • Baffled & Cyclonic (2)
  • 1-Slot (4)
  • Liquid,Solid (1)
  • Scott (2)
  • Oil,Water,Particulate (1)
  • Peristaltic (2)
  • Water,Oil,Dirt (1)
  • 3-Slot (3)
  • Compressed Air (1)
  • Cyclonic (3)
体积容量
  • 125 mL (174)
  • 500 mL (120)
  • 50 g (50)
  • 50 mL (28)
  • 100 mL (31)
  • 400 g (32)
  • 200 g (23)
  • 100 g (26)
  • 15 mL (17)
  • 500 µL (4)
  • 250 mL (7)
  • 0.25 mL (1)
  • 1.5 mL (1)
  • 0.5 mL (2)
  • 1 Gal (4)
  • 200 µL (2)
  • 1 L (1)
  • 5 mL (2)
  • 1 mL (2)
  • 3 mL (2)
  • 5 Gal (1)
  • 4 mL (2)
  • 62.5 mL (3)
  • 100 µL (2)
  • 4.5 mL (1)
  • 1000 µL (3)
  • 2000 µL (1)
  • 7.5 mL (1)
  • 10 mL (1)
  • 13 mm (1)
  • 6 mL (1)
  • 2 mL (3)
  • 2.5 mL (1)
  • 300 µL (1)
  • 1000 mL (5)
  • 20 mL (1)
  • 100 µg/g (1)
  • 14 mL (1)
  • 1.02 mL (1)
  • 75 mL (1)
  • 5 x 500 mL (1)

1-12 の 1358 产品与服务

  • Jump to:
Business Insights (17)
Filters:

Filters :

資源庫
  • Application Note (10)
  • Flyer (2)
  • Specification Sheet (2)
  • Brochure (2)
  • Technical Note (1)

1-12 の 17 Business Insights

  • 产品手册

    OilExpress 4 Oil Condition Monitoring System

    The OilExpress 4 system adapts to your laboratory’s needs, from dozens to thousands of samples per day. Its modular design makes it possible to scale up your sample throughput or separately utilize the oil dilution capabilities in busy laboratories that are using ICP analysis. The system minimizes your operational costs by reducing instrument downtime, increasing throughput to reduce cost per sample, and offering significant savings from decreased solvent waste.

  • 产品手册

    Lubricants Analysis - Complete Solutions for Your Lab

    With throughput demands continually increasing, and an ongoing need for more detailed sample information, PerkinElmer systems are setting the standard for speed and productivity in all areas of lubricants analysis: 1.) Wear metals analysis, 2.) Oil condition monitoring and 3.) Confirmatory testing. Modular and scalable, each solution can adapt as your needs change—no matter what the size of your organization or the demands of your application

  • 应用文献

    Fast Digestion Analysis of Lead and Cadmium in Rice Using Graphite Furnace Atomic Absorption

    Lead (Pb) and cadmium (Cd) are common pollutants in grains and are extremely toxic. Pb is harmful to human organs even at trace levels, and once it accumulates in the body, it causes inhibition of hemoglobin formation and neurological disorders. Cd is even classified as human carcinogen [Group 1 - according to International Agency for Research on Cancer]. It is reported that Cd leads to severe kidney problems which can be fatal and is also associated with brittle bones and liver problems. Rice, as the most widely consumed cereal grain in Asia/China, can quickly pick up Pb and Cd from toxins, pesticides and fertilizers in the soil, thereby endangering the health of millions of people through their diet. Therefore, it is extremely important to develop a simple, reliable method to monitor the levels of Pb and Cd in rice. According to Chinese national standard GB 2715-2016 Hygienic Standard for Grain, the maximum concentrations of Pb or Cd in grains must be below 0.2 mg/kg; the allowable level in the European Union is the same [EC 1881/2006]. The official technique for the determination of heavy metals in both cases is graphite furnace atomic absorption spectroscopy (GFAAS, GB/T 5009. 12-2017, GB/T 5009-2017. 15 and EN 14083:2003). Samples can be pretreated using various methods, including microwave digestion, hot block digestion, dry ashing, and hot plate digestion. It is found that these conventional digestion procedures are always complicated and time-consuming (two-four hours or even longer). Plus, conventional sample preparation techniques require large quantities of corrosive and oxidizing reagents, increasing the chance for contamination which could lead to inaccurate results. Special PTFE vessels are needed for microwave digestion; however, reusable utensils might also cause cross contamination.

  • 应用文献

    Analysis of In-Service Oils Following ASTM D5185 with the Avio 200 ICP-OES

    With heavy machinery, it is important to assess its status during operation to prevent breakdowns and costly repairs. A key aspect is monitoring the status of the oil or lubricants used to lubricate various components such as engines, transmissions, gearboxes and many other important areas: if the oil degrades too much or becomes highly contaminated, it can damage various components. Because of its importance, ASTM created a method for the analysis of in-service oils: method D5185.

  • 应用文献

    Fast Digestion Analysis of Lead and Cadmium in Rice Using GFAAS with Deuterium Background Correction

    Toxic elements, such as lead (Pb) and cadmium (Cd), are entering the food chain through environmental contamination. Rice, as the most widely consumed cereal grain in Asia, can quickly pick up Pb and Cd from soil, thereby seriously endangering human health through diet. These toxic element levels need to be carefully monitored. Maximum levels of Pb and Cd are strictly regulated in Asian countries, especially in China; therefore, it is extremely important to develop a simple, reliable method for trace levels of Pb and Cd in rice. The allowable maximum levels of Pb and Cd in grains in EU and China are required to be below 0.2 mg/kg (Commission Regulation EC 1881/2006 and Chinese GB 2715-2016 Hygienic Standard). Graphite furnace atomic absorption spectroscopy (GFAAS) is the officially recommended technique for detection of trace elements in various food stuffs (GB/T 5009.15-2017, GB/T 5009. 12-2017 and EN 14083:2003). Food samples are usually pretreated before GFAAS analysis using various methods: microwave digestion, hot block digestion, dry ashing, and hot plate digestion. These conventional digestion procedures are usually complicated and time-consuming (2-4 hours or longer). Plus, they require large quantities of corrosive and oxidizing reagents, increasing the chance for contamination which could lead to inaccurate results. However, fast digestion can effectively speed up the sample preparation procedure while reducing the use of corrosive reagents and the chance for contamination.

  • 应用文献

    Analysis of Impurities in Nickel with Avio 500 ICP-OES Following London Metal Exchange Guidelines

    The London Metal Exchange (LME) issues specifications for a variety of purities for different metals. This work focuses on the analysis of contaminants in nickel with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Primary Nickel” as a guideline for the analytes and required concentrations.

  • 应用文献

    Meeting the Challenges of Soil Analysis with the Avio 200 ICP-OES

    The analysis of soils for elemental contents presents challenges during the sample preparation step. A common method for preparing a soil sample for inorganic elemental analysis involves digesting the soil sample in an acid that is heated to near-boiling to extract the elements for analysis. When using open vessels in heating blocks, this extraction method typically takes four hours or more to complete. The sample must then be centrifuged or filtered to remove solid particles prior to analysis. The use of a microwave digestion system can speed this up significantly by completing the acid digestion in less than 50 minutes.

  • 应用文献

    Impurities in Lead with the Avio 500 ICP-OES Following London Metal Exchange Guidelines

    The London Metal Exchange issues specifications for a number of different metals in several grades. This work focuses on the analysis of lead of different purities with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Standard Lead1” as a guideline for the analytes and concentrations.

  • 应用文献

    Analysis of Oil Additives Following ASTM D4951 with the Avio 200 ICP-OES

    When blending base oils and additives for use as lubricants, it is important to know and control the concentrations of certain elements for optimal performance and longer engine life. This work will focus on the analysis of additives in new oils using PerkinElmer’s Avio™ 200 ICP Optical Emission Spectrometer (ICP-OES), which overcomes limitations of other ICP-OES systems and X-ray analyses.

  • 应用文献

    Using MSF to Resolve Difficult Interferences in Metallurgical Samples with the Avio 500 ICP-OES

    The analysis of trace metals in metallurgical matrices also presents a challenge for ICP-OES: spectral interferences. Many elements have a large number of emission lines (i.e. approximately 20,000 for iron), which increases the potential for spectral interferences. This effect is compounded in metallurgical samples, where the matrix element(s) are present at high levels due to the minimal dilutions used.

  • 应用文献

    Analysis of In-Service Oils Following ASTM D5185 with the Avio 500 ICP-OES

    Globally, heavy machinery is used in construction, mining, and a variety of other areas. As the scale of the operations increase, the size, complexity, and cost of the equipment also increase, meaning that breakdowns can be costly, both in equipment repair and lost revenue. As a result, preventive maintenance is paramount. Lubricants are among the key fluids that can be tested, especially the oil used in engines. By monitoring the elemental concentration of the oil or other lubricants (hydraulics, transmission, gear), the status of that compartment can be determined.

  • 应用文献

    Analysis of Wastewaters Following US EPA 200.7 Using the Avio 500 ICP-OES

    This work focuses on the analysis of wastewaters following the guidelines provided in U.S. EPA Method 200.7. The U.S. Environmental Protection Agency (EPA) developed Method 200.7 for the determination of metals and trace elements in waters and wastes by ICP-OES, with the current version being Revision 4.4.1 While the scope of this method allows it to be applied to a variety of sample types, a common application is wastewater analysis.

  • Jump to: